Seismic Film Specifications

Product Description Solar Heat Rejection Glare Reduction UV Transmit Peel Strength (lb./inch) Break Tensile (lb./inch) Elongation at Break
GGL 400 Clear 20.0% 1.1% <1.0% 5-7 125.0 >150%
GGL 400 Gray 35 Gray 56.5% 1.1% <1.0% 5-7 125.0 >150%
GGL 400 Solar 15 Silver 75.6% 81.2% <1.0% 5-7 125.0 >150%
GGL 400 Solar 35 Silver 75.6% 81.2% <1.0% 5-7 125.0 >150%

* All the above films meet ANSI Z97.1 and CPSC 1201 Category II

Download the Glass-Gard Seismic Mitigation Specification (PDF)

Further Information

Seismic film applications can be considerably more effective when the glass and film are anchored to the window frame. For more information, please see our anchoring systems page.


Note: These test data contain only results arrived at after employing specific test procedures and standards. The included data do not constitute a recommendation for, endorsement of, or certification of the product or material tested. These data are provided for informational purposes only and are not to be considered part of the basis of any bargain or transaction involving Viking Window Films. VWF makes no representation or warranty, expressed or implied, including the implied warranties of merchantability of fitness for a particular purpose, that its product will conform to these test data. The product's limited warranty should be carefully reviewed prior to purchasing any VWF product. Extrapolation of data from the sample or samples relating to the batch or lot from which data were obtained may not correlate and should be interpreted accordingly with caution. VWF shall not be responsible for variations in quality, composition, appearance, performance, or other feature of similar subject matter produced by persons or under conditions over which VWF has no control.