Test Data
| TEST REPORT# | CHARACTERISTIC TESTED | TEST STANDARD | FILM TYPE | RESULTS |
|---|---|---|---|---|
|
INTERTEK INTERTE5 INTERTE6 |
Impact Resistance |
16-CPSC 1201 Safety Glazing |
4 & 7 mil | Passes Category I & II |
|
INTERTE5 INTERTE6 INTERTEK HUNTING, 1-1 |
Weathering |
16 CPSC 1201 Safety Glazing |
4 & 7 mil |
Meets the requirements of section 1201.4(e) 1(iv) and 2(iv) |
|
INTERTEK1-1 |
Impact Resistance | ANSI Z97.1 | 4 & 7 mil | Passes Unlimited Requirements |
|
INTERTEK1-1 |
Weathering | ANSI Z97.1 | 4 & 7 mil | Meets the requirements of section Z97.1.5.3.1 |
|
INTERTEK1-1 |
Impact Resistance | ANSI Z97.1 | 4 mil NSN 70, Grey 35, Solar 15, Bronze 20 | Passes Unlimited Requirements |
|
WELMARK |
Impact Resistance | BS 2606 | 4 & 7 mil | Passes |
|
SSFP96-2 |
Impact Resistance |
Din A1 Din A3 |
14 mil one-side 14 mil two-sided |
Passes |
|
CELOTEX2 |
Tensile Strength | ASTM D882-95a |
4 mil 7 mil |
24,196 PSI 25,371 PSI |
|
CELOTEX4 |
Puncture Test | ASTM D882-95 |
4 mil 7 mil |
76.9 LBF 162 LBF |
|
CELOTEX3 |
Peel Adhesion |
ASTM D3330-96 ASTM G26 |
4 & 7 mil | 5.5 lbs/in pre-Weathered 10.3 lbs/in Weathered |
|
CELOEX1 |
Surface Abrasion Resistance | ASTM D1044-94 | All Safety Security Film | Delta Haze-1.94% |
|
CELOTEXA |
Tear Resistance | ASTM D 1004-94 |
4 mil 7 mil |
11 LBF 22 LBF |
|
INTERTE1 ETLASTM1 |
Ignition Properties of Plastics | ASTM D 1929-91 | 4 & 7 mil |
Flash Ignition Temp. 530C Self-Ignition Temp. 550c Time to Ignition 1:23 min |
|
INTERTE4 |
Surface Burning Characteristics | ASTM E84-97 | 4 & 7 mil |
Flame Spread Index-10 Smoke Developed Index-10 |
|
INTERTE2 |
Rate of Burning | ASTM D635-88 | 4 & 7 mil | Material did not stay ignited long enough to get a reading |
|
INTERTE3 |
Ultra Violet Light Transmission | ASTM E1348-90 | IG Unit w/4 mil Film on Surface 2 and 3 | Blocks 99.9% of U |
|
ATL97-06.02 |
Wind borne debris | Dade County Small Missile Test | 4 mil | Meets the requirements of PA201 and PA203 standards up to 50 PSF |
|
WBE |
Bomb Blast Mitigation | GSA's Method for Glazing Systems Subject to Air Blast Loading* | 12 mil** | Performs to GSA Hazard Level 3 |
|
HPWHITEH |
Ballistics .38 Special | HPW-TP-0500.02 | 12 mil on 3/4 glass | No Penetration-3 shots |
|
HPWHITEH.02 |
Ballistics 9mm | HPW-TP-0500.02 | 12 mil on 3/4" glass | No Penetration-3 shots |
|
WPWHITEH.022 |
Ballistics .38 Special | HPW-TP-0500.02 | 12 mil on 1/2" glass |
3 shots 2-no penetration 1-penetration |
|
ETLASTME |
Sound Transmission Loss Text |
ASTM E90-9- ASTM E413-87 |
4,7 & 12 mil | No Loss of Sound Transmission |
Abbreviation Table
| ANSI | American National Standards Institute |
| ASTM | American Society for Testing and Materials |
| BS | British Standards |
| CPSC | Consumer Products Safety Commission |
| GSA | General Services Administration |
| LBF | Pounds Force |
| MIL | Thickness Measurement |
| PSI | Pounds Per Square Inch |